Again, I suggest you follow this example installation to the end to have a good understanding of what you will be doing and then make your decision. I recently (3 months ago) installed a new Trane 2 stage ECM furnace and along with it an Aprilaire 600 whole house Humidifier. Increases home value—humidifiers are rather inexpensive but add value to your HVAC system, thus your home. Like most products, it just takes proper care...I highly recommend having a humidifier. Hello Dan. This is how you place the nut and ferule onto the 1/4" water line you are about to connect. (2-Pack) Replacement Humidifier Pads / Filters fits Aprilaire Models 350, 360, 560, 568, 600, 600A, 600M, 700, 700A, 700M, 760, 768. Notice how it's above the coil and facing the humidifier casing. This can cause wood to take in too much humidity and ice to form on windows. Once your humidifier installation is complete—and you've checked that all of your plumbing connections are leak free—you can run a test to make sure it's operating properly and set your desired humidity level. Place your flat head screwdriver against the duct at a slight angle and hammer it into the metal. Search Help by Model. Alternatively, you may want to drill a screw in the duct and remove it for an easier start. Once you find a level that you're comfortable with, mark it on the humidistat so that when you shut down the humidifier for the summer, you'll know where to set it again when cold weather swings back in. The drain must be at the bottom or all the water will run all over the place. The Aprilaire Model 600 Humidifier is one of the best-performing bypass humidifiers on the market. With the tube connected, tighten the valve down to pierce the main. The Aprilaire 600 is easier than ever to install because it includes a built-in bypass damper, which means fewer parts to install. It's suggested to be at least 6" above the unit. This will produce an evaporative capacity of 0.70 gallons per hour. Thinking About Buying a Whole-House Humidifier? Then, just securely press the black connector onto the HUM terminal and the white connector onto the NEUTRAL. It offers all of the performance benefits of Aprilaire's more advanced humidifiers including Automatic Digital Control which automatically adjusts humidity based on outside temperature. The casing has holes at the top and bottom of the damper connection for this. The take off is installed at the top left in this photo. Make sure you adjust the elbow first and check that the damper can swing freely. How to Clean Air Ventilation Ducts Yourself. Aprilaire 600 - do I need to install a transformer? The only time you have to worry about mold with a humidifier is if it's not used properly. This humidifier can be installed on the supply or return air ductwork. Aprilaire 4231 yellow orifices are the tiny nylon components which, accurately meter the flow of water into your humidifier. I don't remember off the top of my head however I know it's quite simple. You can use pieces of your scrap metal for strapping. I really can't say for sure on a specific board but I do know the neutrals are often sectioned off on their own sort of and if they are all occupied there spade terminal splitters you can get that will turn a single into a double. Manuals and User Guides for Aprilaire 600. Any suggestions will help. A Todd Arthurs Company, Inc, Split-System Central Air Conditioners and Heat Pumps, Central Heating & Cooling Complete Systems, Split-System Installation Supplies & Components, Self-Contained Package Unit Air Conditioning w/ Heat Option, Hotel-Style Heating and Cooling Units (PTAC), Heat Pump Central Air Conditioning (Electric Heat and Cool), Aprilaire 600-Series Humidifier Installation Instructions (600A Model 60), Aprilaire Humidifier Replacement Parts List (Current Models), Aprilaire 600-Series Humidifier Installation Instructions (600A Model 58), Aprilaire 60 & 62 Installation Instructions, Humidifier Install Instructions for Fiberglass Duct, Aprilaire New and Old Humidifier Plenum Opening Sizes, Allows you to check relative humidity level, Tells you when it's time to change the water panel. It doesn't matter which color goes to which side; just remember where they're going. Remember, edge to edge plus 3". Visualize your drain path to be sure you'll be able to maintain a downward slope towards its destination. Dan has been in the HVAC industry for 23 years with experience ranging from installation and service to sales and distribution. The Aprilaire Automatic Humidifier Model 600 is the newest addition to the aprilaire humidifier line. Had 2 room humidifiers that couldn't get humidity past 23 percent. I have bought the same humidifier but with automatic humidistat control [600 model]. You can install a humidifier on ductboard and as long as it's installed proper you'll be fine but that goes for any install. The Aprilaire 600 whole home humidifier is a bypass humidifier which is mounted on a 6-inch bypass duct that connects the return and supply ducts, bypassing the furnace. Tap into the drain by cutting in a "tee". Do a little at a time. I have the Aprilaire 500m unit. Hey Dan - is it an issue to install a humidifier horizontally? Measure to cut your 6" warm air pipe to fit and finish up your bypass. Variety of aprilaire 600 humidifier wiring diagram. Pliers – You will want two pairs of standard pliers or channel locks. Is the wiring to the humidistat is any different or it is the same? In this aprilaire humidifier consumer reports post, we will introduce 5 best rated apirlaire humidifiers, and makecomparisons between them: Aprilaire 400 vs. humidifier 600 vs. 700 vs. 800. Humidifiers and Dehumidifiers - Can I install Aprilaire 600 on return duct? You should bump up your humidistat until you're comfortable (without making your home too damp). Power-Fan humidifiers can be installed on a vertical run of either the supply or return plenum and uses a fan to distribute humidity into the air stream. Adding a whole-house humidifier to your heating and air conditioning system is something you can do yourself to improve your air quality and comfort. Honeywell Power Humidifier Wiring Diagram. A picture is worth a thousand words, so why don't I keep this as simple as possible? Pull off the control knob so that you can pull the facing off of the main control body. I've seen advertisements for the Aprilaire humidifier, and have been seriously tempted. This ensures proper drainage and prevents stagnant water from building up in the line. Thanks for putting so much effort into this article. Due to lower plenum temperatures the unit should be connected to your hot water supply line. Your humidifier installation is done if the test cycle was good. Ask a customer care specialist We have a trained team ready 24/7 to answer your questions and help you get back on track. The amount of water vapor that can be delivered into the home, measured in gallons per day (GPD), that the humidifier can deliver into the space. I did notice however that on my furnace circuit board, next to HUM it says 24v. These are signs that your water panel needs replacing. Install the saddle valve on the hot water line with the discharge pointing toward the humidifier. Install PVC drain between "tee" and humidifier with the path of least resistance. Prevents skin from drying and itching and lips from chapping. Here, I protected my wiring from the duct to the furnace. Below are photos of these parts as well as a brief description of each one for easy reference, should you need them. read complete safety instructions and installation template before starting installation template must be level readreversesidefirst! I have good water flow. It is probably just a matter of tightening the connections a bit more, but worst case scenario—you can install an inline valve and make the repair to the main at the same time using push fittings. Below, I've listed the steps for my Aprilaire 600M installation example, but you don't lose anything to your imagination, I've provided pictures to go along with these steps. I have everything hooked up as you described. The Model 600 and 600M Aprilaire can be installed on either the supply or return plenum of a forced air handling system and is easily reversible for installation with right hand or … This will force the unit to operate. Install the 6" elbow to the casing. A remote sensing bulb is a small (about ¼” round) sensor that mounts outside the home and connects by light gauge wire (18 to 22 gauge, 2-conductor) to the humidifier controller. The rest of the wiring is basically a circle going from the furnace to the stat (red), from there to the humidifier solenoid (red still) and back to the furnace (white/common). (all three are currently in use) If so, does it matter which one I hook up to? Just keep this in mind: Here are the connections to the humidifier control. The 600 can be configured with the 6" bypass duct connection on the right or left side. Follow up to my last post, the circuit board is a Nordyne 624790-A for reference. But the wiring still confuses Me. View more. Tighten the two by using one plier to hold the valve and the other to tighten the nut. Ask your local Aprilaire professional today for a free in-home comfort assessment and indoor air quality consultation. It takes humidifier innovation to the next level and performs as good as it looks! If all is well, replace the cover on the humidifier and adjust your humidity control to your liking. Included in the box: Installation instructions and template, humidifier with built-in bypass damper, 24 VAC transformer, automatic digital humidifier control and outdoor temperature sensor, saddle valve, solenoid valve, and water panel. Red is just a continuation from the transformer to humidistat. Depending on the model you choose, the labor rate and the service time, this cost could range from as low as $200 to as high as $1,000.The typical range is $395 and $734.Average units cost about $100 to $300, while higher-end options cost $500 to $1,100.Labor by HVAC technicians … You will have the opportunity to view our recommended accessorices after adding a product to your cart. Where else can I hook the white wire from the transformer? I put a new powerd April air on and my hum numbers are real low. I have my Aprilaire 600 physically installed and plumbed and I'm ready to tackle the wiring. Put the knob back on the control post. Enter your zip for personalized product and service recommendations. If you don’t have one, you can probably find it on the internet. Be sure to glue the fittings and secure the pipe. Remember, the shorter and straighter the bypass, the better. We have 19 Aprilaire 600 manuals available for free PDF download: Service Manual, Reference Manual, Application Manual, Safety & Operating Instructions Manual, Owner's Manual, Safety And Installation Instructions, Safety Instructions And Installation Template, Installation Instructions It sounds like you have an upgraded model. White is from the humidistat to humidifier unit and from unit back to the transformer. I am wondering if it's the 24v converter. If you have an HVAC contractor perform the installation for you, the cost will still be "earthly" and in the neighborhood of $400-$500. Start a live chat As far as maintenance goes, just replace your water panel as needed. Bottom: humidifier casing. The Aprilaire 600 includes a 5-year manufacturer's warranty. They are very helpful. 700 760 768. aprilaire 600 humidifier wiring diagram – A Novice s Overview of Circuit Diagrams. Modern furnaces have terminals on the circuit board marked HUM and NEUTRAL for easier humidifier hook up. Includes automatic digital control humidistat, sensing bulb, water pad, 110v to 24v transformer and manufacturer's special instructional DVD. Significantly reduces the amount of airborne dust in the home, thus reducing the suffering of those with allergies. Now that we've decided adding a humidifier is a good and affordable idea, let's get started with installing a unit ourselves using a rather basic Aprilaire humidifier as an example. I have an automatic 500 aprilaire with outside temperature. Perfect for loosely insulated houses around 1,000 sq ft. and tight houses up to 4,000 sq ft. Your options may be limited by your existing heating and cooling system's set up. You can mount to the supply side, but the system works much better on the return side and poses less of a threat to your furnace, should there ever be a malfunction involving water and electrical components. There should be a neutral section on the board that's common to all the 110 circuits, it just may not be located right there by the HUM terminal. Aprilaire Model 60 Digital Humidistat This sensor provides temperature readings to the computerized controller which allows the humidifier to automatically adjust humidity levels in the home based on outside air temperature. But, first off, I got Aprilaire 600 … It is also left or right side reversible. Aprilaire 600M Humidifier Installation Walkthrough - YouTube Other items needed for the installation that are not included: 1/4" copper tubing for water line, 1/2" ID plastic tubing for drain, 6" round ducting & elbow for bypass air, 2-conductor 18 to 22 gauge wire. Plus, the damper is conveniently labeled for summer and winter settings, allowing you to set it for the entire season with no guesswork involved. Connect your 6" elbow to the humidifier casing with two 1" screws. I have it hooked up to the HUM and NEUTRAL as you describe. Hi: I have an almost new Williamson oil FHA furnace, with a Aprilaire 600 humidifier and an Aprilaire Model 60 Humidistat. Now, slide the teeth of the take off or collar into the hole and fold them over to lock it in place. I poked a hole in the duct and inserted the wires from the humidifier to hide my connections. Great product! Static Sparks flying everywhere! 40 Can you install on installation foam board as I don’t have metal ductwork. Jayme - Yes. My circuit board has the HUM (110v) terminal but no neutral terminal. Will wiring be different for me. (10-Pack) Replacement Humidifier Pads / Filters fits Aprilaire Models 350, 360, 560, 568, 600, 600A, 600M, 700, 700A, 700M, 760, 768. They allow a specific amount of water to go into the humidifier, unique to your model humidifier. Be sure to glue each joint and secure the pipe to the furnace or duct with 1/2" screws. The cost of installing or having a heating and cooling professional install a humidifier for you is really rather reasonable. Ft. 4.6 out of 5 stars 3,377 $176.40 Aprilaire units are able to be flipped around so that the bypass can be on either side. The two combined should give you a very clear sense of how to install your own humidifier. My furnace is a MSS9/CSS9 and I also have a DuroZone RED-4 zone controller. If you don't have these terminals, you'll have to tap into another 110V source using wire nuts. Wondering if it is already at 24v, and the converter isn't needed? You can measure edge to edge plus 1" to get your cuts for straight pipe. The Aprilaire Model 600 Humidifier is a whole-home solution that helps you achieve total comfort through humidity control. Aprilaire - The large capacity bypass humidifier is a whole-home solution that helps you achieve total comfort though humidity control. Whether it be the Aprilaire unit I used in this example or any other humidifier brand, all of this information is applicable, and the project should only take about four hours to complete for the average homeowner. However, with so many options and situations, I've provided photos and a wiring diagram that I believe will give you a better idea of how to tackle your specific needs. - Ok. Shiva - it is different because you have an outdoor sensor you have to wire in but your instructions should tell you how to do so in your specific application. Finish the bypass by taping the joints and installing two screws to each joint. The water panel casing holds the water panel. This humidifier can be installed on the supply or return air ductwork. Aprilaire 700 Wiring Diagram Lorestanfo. Be sure everything is securely tightened but not overtightened. Once you've cut the line and completed the install of it, twist the valve "tee" handle all the way down to pierce the main and then loosen it to open the valve and allow water to flow to the humidifier. Shasta Matova from USA on March 03, 2014: Congratulations on being one of the top 10 hubs for Friday. The Aprilaire 600 bypass humidifier also includes the option to install an outdoor temperature sensor (also included) that works in conjunction with the automatic humidistat to properly monitor and adjust relative humidity settings in the home. The humidistat cover will also just snap into place. It's upstate New York here, I've been setting the the thermostat to 73 degree, so furnace officially started working since late September. Features: Features a built-in bypass damper, which means fewer parts to install Delivers up to 50% more moisture than competitive units Has an evaporation capacity of … The 24V humidifier wiring is done in a very simple series. Snap the panel back into the humidifier by putting the bottom in first and snapping the top back into the humidifier housing. Top left: the control for this system's zoning. Power-Fan Humidifiers require 110 AC plug-in power to run the fan, as well as a 24v switch from the furnace board. Content is for informational or entertainment purposes only and does not substitute for personal counsel or professional advice in business, financial, legal, or technical matters. Aprilaire Humidifier Reviews 2020 – Top 5 Best Aprilaire Humidifiers. Place the doors back onto the furnace and turn the humidistat all the way up or to the "test" marking. The Aprilaire 600 Bypass Humidifier is a whole-home solution that helps homeowners reach their optimal indoor comfort through humidity control. Use pliers to squeeze your spade connectors onto the transformer's black and white wires. Easy to follow installation instructions. Run a test cycle and replace the cover. People who say their humidifier caused mold usually have it set too high and/or forget to shit it down in the winter. Equipment installation now available in your area. The last part of the install is to wire it up. Any wiring outside of the duct from the ceiling down should be protected by some sort of flexible conduit. Be sure you don't tie into the 24V common by mistake. Again, I think the photos will help you the most, so as you look at those, keep in mind: In case there is a problem once you pierce the line, you'll have to shut off the water to that pipe to stop the leak and fix the issue. Even if you have to purchase a tool or two, you'd likely get out of the HVAC system upgrade for around $300 since you likely have most of the tools you need. BYPASS & POWER-FAN HUMIDIFIER ACCESSORIES AND PARTS, BYPASS & POWER-FAN HUMIDIFIER INSTALLATION KITS, BYPASS & POWER-FAN HUMIDIFIER REPLACEMENT PADS / FILTERS, © Copyright 2002-2021, Alpine Home Air Products. Remove the cover and water pad from the humidifier and place the casing into the cutout on the duct. It does not have to be located on the same side of the return air duct. A very first look at a circuit layout might be confusing, however if … Learn how here. Hello Millionaire Tips. Next morning house was 28 and settled in at 31 percent next day. Make sure you make good connections. Helps but it still didn’t work. In the corner of the board, it has two terminals labeled "LINE N" and a terminal labeled "XFMR N", are these the dedicated neutrals I can hook up to? Features. Make sure the rubber gasket is seated properly, the "tee" handle is tightened to the mounting bracket, and the valve needle is retracted when mounting the valve to the hot water line. You can remove the hose to see if the water is coming, but when you do, make sure you point it at the panel near the bottom to catch the water. Please enable your browser's cookies to use this site. I would like the humidifier to run when the fan comes on independent of the heat. Helps keep house plants healthy—looking at dying plants doesn't conduce a feeling of comfort. The Aprilaire 600 is easier than ever to install because it includes a built-in bypass damper, which means fewer parts to install. Make sure there is enough room above the unit to mount your humidistat. Don't forget the foam gasket that goes between the humidity control body and the duct. If static is still keeping you from wanting to be near your loved ones, and you feel that the air is still dry, the level is likely too low. Be sure the bypass damper can swing. PVC pipe and fittings, wire nuts, spade terminals, screws, wire ties, and thermostat wire. Again, the shorter, the better. This is where the work is done so it then sends the negative voltage back to the common on the furnace and that's it. Notice how the needle is recessed into the rubber gasket and that the gasket is seated on the valve so that the curvature of the two match up. You may find that you already have tools that can be used as substitutes for some of these HVAC specialty tools. Since it has a manual humidistat, and a 24V solenoid, and I have a new high efficiency Trane XB90 furnace with HUM terminals, seemed easy enough. Turn the humidistat all the way up or to the "test" level. It offers all of the performance benefits of our other technologically-advanced computer-equipped automatic humidifiers and it’s easier than ever to have installed because it includes a built-in bypass damper, which means fewer parts to install. Using 1" long sheet metal screws, mount the casing to the duct by running screws through the provided holes in the casing. The Model 600 uses the furnace blower to move air through a water panel. If you're doing it yourself, you can expect to spend around $250 for the unit and necessary materials to install it. Designed to work in large to mid-sized homes, the Aprilaire 600 efficiently humidifies up to 4,000 sq feet and dispersing 17 gallons of water daily. It largely depends on the water that it uses and the home that it's in. Consider waiting 4-5 days before fine-tuning the settings. Besides cutting down on your use of moisturizers and boiling pots of water on the stove, here is a list of benefits a whole house humidifier will provide to help pay for itself. Purchased Aprilaire 600. Make sure the power to the furnace is turned back on and that the main thermostat is set high enough to make the furnace run. It reveals the elements of the circuit as streamlined shapes, and the power as well as signal connections between the gadgets. Slide the nut and ferrule up to the valve. Bypass Humidifiers only require the 24v switch from the furnace. If ordered by 1 p.m. CST M-F, ships same day. One of the best things about humidifiers is that they're so simple to maintain and there are only a couple of working parts. That being said, 35-45% is the suggested range for most of us, but we want to ease into that. Tip: Change your filters after you do your spring cleaning since you'll likely be stirring up dust. Thank you for the instructions. Lowers or even eliminates static electricity. Before we start cutting holes into our ductwork, we need to decide where we're going to install our humidifier. Aprilaire 600 Whole Home Humidifier, Automatic High Output Furnace Humidifier, Large Capacity Whole House Humidifier for Homes up to 4,000 Sq. Please email us anytime if you have questions: support@arnoldservice.com Don't over tighten anything, and use two pairs of pliers to make sure you don't twist things as you tighten. The furnace does not have a white terminal on the terminal strip, and Aprilaire tells me that the only way to run this thing is with it set so the blower runs whenever the humidity is too low, whether or not the furnace is on. I might have a few more questions since it's my fisrt time doing it. Thanks! Be sure you have room to remove the unit's cover, water pad/panel, and other parts for easy maintenance and repair in the future. Put your spade connectors on to your transformer wires. Or do you think I just need to tap into a different power source? Aprilaire 600 Installation Instruction Author: Aprilaire - Bel-Aire ElectronicAirCleaners.com Subject: Bypass Flow-Thru Humidifier Install Keywords: Aprilaire 600 Whole House Humidifier Created Date: 3/21/2004 7:58:26 PM If you're going to hire a heating and cooling service provider for your install, perhaps you'll want to skip down to the maintenance and humidity control sections of this page. Without further delay, let's start installing our humidifier! You can confirm this by listening for the "click" of the solenoid valve open and for the flow of water and drainage coming from the unit. The stat acts as a switch triggered by the humidity reading so that it won't come on unless the humidity is less than what you a setting it to call for so the 24v just goes to the stat when the heat comes on but only makes it to the solenoid if the stat then "closes the bridge" allowing it to pass to the valve so it will open. If you don't have a drain already, you can run the pipe along the floor to a laundry drain, or you'll have to add a condensate pump to pump the water to its destination. This humidifier kit gets you started but you'll still need a couple items to go with it. Do you have to worry about mold with a humidifier? Don't over tighten, but be sure the wire is secure in whatever terminal type you're using. But not getting power to the solenoid. The air flow can run in either direction, in to the 6" bypass opening or out of the bypass opening. 58 Inspirational Aprilaire 600 Installation Wiring. The Model 600 uses the furnace blower to move air through a Water Panel® and is one of the … The Aprilaire Automatic Humidifier Model 600 takes humidifier innovation to the next level and performs as good as it looks! Enter your zip code and find a pro. Red is from the transformer and white goes to the humidifier. 24v Bypass Model w/ Automatic Digital Control & Humidity Readout. Aprilaire Model 600 Humidifier. Deters the spread of viruses that thrive in drier environments. Aprilaire - 35 A2 35 Replacement Water Panel for Whole House Humidifier Models 350, 360, 560, 568, 600, 600A, 600M, 700, 700A, 700M, 760, 768 (Pack of 2) 4.8 out of 5 stars 11,386 $18.40 $ 18 . If windows and horizontal surfaces feel damp, the level is too high. Very helpful. Simple as pie. Sorry this feature requires JavaScript. The NEUTRAL is for 110V use. … Black to HUM and white to the 110V Neutral. Here are a few things to keep in mind—I've applied them to this home humidifier install. Aprilaire Partners - Find Aprilaire Distributors to sell Aprilaire Products including Aprilaire Humidifiers, Aprilaire Dehumidifiers, and Aprilaire Air Cleaners. I have on my April aire humidistat r,c,w,h,h,gf,a,b, g,odt, I bypassed it for now so it will run. These easy-to-follow, step-by-step instructions and photos will show you all you need to know to install, operate, maintain and understand your furnace humidifier using an Aprilaire 600M unit as an example. Question: Can the 600 be installed on a horizontal furnace in a home that’s 1,340 square feet? Mount the unit on the return air duct whenever possible. Perhaps this is more than you ever wanted to know about humidifiers, but I wanted to provide a complete guide, not just on installing a whole-house humidifier but also all the things that go with it. Within a minute or so, you should hear the "click" of the humidifier's solenoid valve opening and the water flowing into the water panel. A water panel doesn't have an exact lifespan. If it's summer, close the damper. Thank you for reading! Try to make the bypass connection as short and straight as possible. You should have wiring diagrams in with the unit you bought that will help with yours. Your manual should show that. Either your browser does not support JavaScript, or it has been disabled. Connect your red and white low-voltage wires to the transformer. Start at 30% and let the humidity settle into the home before deciding to make adjustments.